Strona 2

Placement and Use of Components CM6300CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.c

Strona 3

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.comThermister (Temperature Sensor)Every 2 Way LCD Firstech RF kit includes an o

Strona 4

The CM6 Series Blade connector has a locking tab. Older blade harnesses will work but you must cut the notches on the black harness plug off.Blade sys

Strona 5

Connector 1 (CN1), 4-PinPin 1 Red - Constant 12V positive (+) power input. This wire must be connected. The proper vehicle wire will test (+) 12

Strona 6

Connector 4 (CN4), 20-Pin: Programmable Output Connector (POC)IMPORTANT: Odd Pin numbers 1 through 17 are programmable for up to 19 different output

Strona 7

Pin 11 Black [POC 5] – Auxiliary 2 250mA negative (-) output. This is an optional output that will provide a programmable output to trigger slidin

Strona 8

Connector 5 (CN5), 6-PinPin 1 Not usedPin 2 Violet/White - Trunk release 250mA negative (-) output. This is an optional output that will release

Strona 9

Connector 7 (CN7), 4-Pin to 4-Pin or 6-Pin (Pre-wired Antenna Cable)Connect your antenna cable to this port. You can only use 4 to 4 pin or 4 to 6 pin

Strona 10

Connector 11 (CN11), 2-Pin (Pre-wired LED)Note: Do not mistake for Thermister port.Pin 1 Black - L.E.D negative (-) ground. Pin 2 Black/White- L.E

Strona 11 - CM6300 Install Guide

Option Programming Tables CM6300Option Group 1Feature Default Setting - IOptional Setting - IIOpt

Strona 12

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.com Table of Contents

Strona 13

Option Group 4Feature Default Setting - IOptional Setting - IIOptional Setting - IIIOptional Setting - IV4-01Aux 1 output 0.5sec Latch0.5 sec Pulse +

Strona 14

Special Option Group 1Feature Setting Value (Seconds)2 AUX1 output time 1 ~ 1003 AUX2 output time 1 ~ 1004 AUX3 output time 1 ~ 1005 AUX4 output time

Strona 15

1-04 Double Pulse Unlock - If enabled, this option will cause the system to double pulse the lock, unlock or both lock and unlock outputs. This

Strona 16

3-04 Starter-Kill – This option determines the mode of the anti-grind/starter-kill relay. Default 1: Anti-grind + starter-kill Option 2: Anti-gri

Strona 17

3-15 Soft Disarm - When a vehicle has a factory alarm, and the Firstech alarm is triggered, you may have both alarms triggered at the same time.

Strona 18

4-07 Aux 2 Input – This option changes the input behavior of the instant trigger wire on the Aux Input Sensor green connector. Default 1:. Will

Strona 19

Special Option Groups 1 & 2 CM6300IMPORTANT: The OP500 is required to change settings in Speci

Strona 20

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.comAt the end of menu 4, if diesel mode or auxiliary setting functions were ena

Strona 21

How To Program Options With 1 Way Remotes With 2 Way Remotes (Wait for chirp between each tap)Scroll Through Menu (Wait for chirp between each tap)Wai

Strona 22

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.com Troubleshooting

Strona 23

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.comCopyright 2011 Firstech, LLC.Page 3

Strona 24

Whenever I try to arm the vehicle, it chirps the siren 3 times and will not arm.A: Check the hood and trunk trigger inputs.Do the door locks flip flop

Strona 25

CM6300 Install GuideAlarm Systemwww.firstechonline.com | www.compustar.comFirstech technical support is reserved for authorized dealers only.Monday -

Strona 26

Introduction CM6300Thank you for purchasing this Firstech system for your

Strona 27

Installation Basics CM6300If you are new to installing Firstech Series Remote Start

Strona 28

Remote Programming Routine CM6300IMPORTANT: Any and all remotes must be coded to the control module pr

Strona 29

Placement and Use of Components CM6300RPS Touch and RPS (Remote Paging Sensor)The RPS is an optional feature.

Strona 30

2 Way LCD remote pagingTo page a 2 Way LCD remote just tap the ‘Red Circle’ twice.Touch Panel SensitivityTo change touch sensitivity open the driver’s

Strona 31

STEP 5: The LED on the RPS will confirm your first number by flashing BLUE slowly. Once the LED begins to flash rapidly in BLUE, enter your second num